Over het archief
Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
one publication added to basket [323186] |
Multi-residue quantification and screening of emerging organic micropollutants in the Belgian Part of the North Sea by use of Speedisk extraction and Q-Orbitrap HRMS
Vanryckeghem, F.; Huysman, S.; Van Langenhove, H.; Vanhaecke, L.; Demeestere, K. (2019). Multi-residue quantification and screening of emerging organic micropollutants in the Belgian Part of the North Sea by use of Speedisk extraction and Q-Orbitrap HRMS. Mar. Pollut. Bull. 142: 350-360. https://dx.doi.org/10.1016/j.marpolbul.2019.03.049
In: Marine Pollution Bulletin. Macmillan: London. ISSN 0025-326X; e-ISSN 1879-3363, meer
| |
Trefwoord |
|
Author keywords |
Pharmaceuticals; Personal care products; Pesticides; High-resolutionmass spectrometry; Belgian Part of the North Sea; Marine contamination |
Auteurs | | Top |
- Vanryckeghem, F., meer
- Huysman, S., meer
- Van Langenhove, H., meer
|
- Vanhaecke, L., meer
- Demeestere, K., meer
|
|
Abstract |
Knowledge about the occurrence of emerging organic micropollutants in the marine environment is still very limited, especially when focusing on the Belgian Part of the North Sea (BPNS). This study therefore optimized and validated a Speedisk® based SPE and LC-Q-Orbitrap HRMS method to tackle the challenge of measuring the expected ultra-trace concentrations in seawater. This method was applied to 18 samples collected at different locations in the open sea and harbor of the BPNS. Forty-eight compounds, among which several pharmaceuticals, personal care products or pesticides described in the EU Watchlist, were detected – some for the first time in seawater – at concentrations ranging up to 156 ng L−1. Moreover, the untargeted screening potential of the newly developed HRMS method was highlighted by revealing the presence of up to 1300 unknown components in a single sample and by assigning molecular formulae to those components demonstrating high discriminative potential between samples. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.