Over het archief
Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
one publication added to basket [246732] |
A reliable liquid chromatography-tandem mass spectrometry method for simultaneous determination of multiple mycotoxins in fresh fish and dried seafoods
Sun, S; Han, Z; Aerts, J.; Nie, D; Jin, T; Shi, W; Zhao, Y; De Saeger, S.; Zhao, Y; Wu, B (2015). A reliable liquid chromatography-tandem mass spectrometry method for simultaneous determination of multiple mycotoxins in fresh fish and dried seafoods. J. Chromatogr. 1387: 42-48. https://dx.doi.org/10.1016/j.chroma.2015.01.071
In: Journal of Chromatography A. Elsevier: Amsterdam. ISSN 0021-9673; e-ISSN 1873-3778, meer
| |
Trefwoord |
|
Author keywords |
Liquid chromatography-tandem mass spectrometry; Mycotoxins; Fresh fish;Dried seafoods |
Auteurs | | Top |
- Sun, S
- Han, Z
- Aerts, J., meer
- Nie, D
|
|
- De Saeger, S., meer
- Zhao, Y
- Wu, B
|
Abstract |
A reliable liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for simultaneous determination of nine mycotoxins, i.e., aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1), aflatoxin G2 (AFG2), ochratoxin A (OTA), zearalenone (ZEN), T-2 toxin, HT2 toxin and deoxynivalenol (DON), in fresh fish (muscle and entrails) as well as dried seafoods. Special focus was given to sample pretreatment which is crucial for an accurate and reliable analytical method. With regards to the high complexity of the matrices, extraction solvent, time, and temperature as well as clean-up cartridges were optimized to improve extraction efficiency and reduce matrix effects. The optimum procedure included ultrasound-assisted extraction with acetonitrile/water/acetic acid (79/20/1, v/v/v) at 40 degrees C for 30 min, defatting with n-hexane and purification by Oasis HLB cartridges. The method was further validated by determining the linearity (R-2 >= 0.9989), sensitivity (limit of detection <= 2 mu g/kg, limit of quantitation <= 3 mu g/kg), recovery (72.2-119.9%) and precision (<= 18.3%) in muscle and entrails of fresh crucian carp (Carassius carassius) as well as dried fish products. The method was proven to be suitable for its intended purposes. Mycotoxins of OTA, ZEN and AFB2 have been found in fresh fish and dried seafoods for the first time. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.