Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
Impact of hydraulic pressure on membrane deformation and trace organic contaminants rejection in pressure assisted osmosis (PAO)
Blandin, G.; Vervoort, H.; D'Haese, A.; Schoutteten, K.; Vanden Bussche, J.; Vanhaecke, L.; Myat, D.T.; Le-Clech, P.; Verliefde, A.R.D. (2016). Impact of hydraulic pressure on membrane deformation and trace organic contaminants rejection in pressure assisted osmosis (PAO). Process Safety and Environmental Protection 102: 316-327. https://dx.doi.org/10.1016/j.psep.2016.04.004
In: Process Safety and Environmental Protection: Rugby. ISSN 0957-5820; e-ISSN 1744-3598, meer
| |
Trefwoord |
|
Author keywords |
Forward osmosis; Pressure assisted osmosis; Membrane deformation; Traceorganic contaminants; Water recycling; Micropollutants |
Auteurs | | Top |
|
- Schoutteten, K., meer
- Vanden Bussche, J., meer
- Vanhaecke, L., meer
|
- Myat, D.T.
- Le-Clech, P.
- Verliefde, A.R.D., meer
|
Abstract |
This study provides for the first time an extensive comparison of trace organic contaminants (TrOCs) rejection by commercial cellulose tri-acetate (CTA) and thin film composite (TFC) forward osmosis (FO) membranes from HTI and Porifera operated under pressure assisted osmosis (PAO) conditions. Commercial TFC membranes allowed for higher water permeabilities, higher selectivities and higher water fluxes in FO and PAO operation, compared to the HTI CTA benchmark. As for HTI CTA, TFC membranes suffered from deformation due to the hydraulic pressure applied in the PAO process. However, not only deformation by stretching of the active layer, but also compaction of the support layer was observed, reducing internal concentration polarisation (ICP) and allowing for flux enhancement. In FO operation, the TFC membranes demonstrated a high rejection (>80% for HTI TFC and >90% for Porifera) of the whole range of tested TrOCs due to steric hindrance. It was also noticed that, being more negatively charged, the TFC membranes allowed for very high rejection of negatively charged compounds, but lower rejection of positively charged molecules, as a consequence of electrostatic interactions. In PAO operation, a general decrease of TrOCs rejection was observed. This could possibly be a consequence of decreasing selectivity (due to membrane deformation), increased TrOCs external concentration polarisation and/or lower reverse salt diffusion (less hindrance of forward TrOCs diffusion). |