Over het archief
Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
[ meld een fout in dit record ] | mandje (0): toevoegen | toon |
Functional comparison between critical flicker fusion frequency and simple cognitive tests in subjects breathing air or oxygen in normobaria Hemelryck, W.; Rozloznik, M.; Germonpre, P.; Balestra, C.; Lafere, P. (2013). Functional comparison between critical flicker fusion frequency and simple cognitive tests in subjects breathing air or oxygen in normobaria. Diving Hyperb. Med. 43(3): 138-142
In: Diving and Hyperbaric Medicine. South Pacific Underwater Medicine Society: Melbourne. ISSN 1833-3516, meer
|
Beschikbaar in | Auteurs |
|
Trefwoord |
|
Author keywords |
|
Auteurs | Top | |
Abstract |
Methods: To test the reliability of this method, the comparison between CFFF and three tests (Math-Processing Task, Trail-Making Task, and Perceptual Vigilance Task) from the Psychology Experiment Building Language battery (PEBL) were used to evaluate the effect of 10 minutes of 100% normobaric oxygen breathing on mental performance in 20 healthy male volunteers. Results: Breathing normobaric oxygen significantly improved all but one of the measured parameters, with an increase of CFFF (117.3 +/- 10.04% of baseline, P < 0.0001) and a significant reduction of time to complete in both the math-processing (2,103 +/- 432.1 ms to 1,879 +/- 417.5 ms, P = 0.0091) and trail-making tasks (1,992 +/- 715.3 to 1,524 +/- 527.8 ms, P = 0.0241). The magnitude of CFFF change and time to completion of both tests were inversely correlated (Pearson r = -0.9695 and -0.8731 respectively, P < 0.0001). The perceptual vigilance task did not show a difference between air and O-2 (P > 0.4). Conclusions: The CFFF test provides an assessment of cognitive function that is similar to some tests from PEBL, but requires a less complicated set up and could be used under various environmental conditions including diving. Further research is needed to assess the combined effects of increased pressure and variations in inspired gas mixtures during diving. |
Top | Auteurs |