Over het archief
Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
A validated analytical method for the determination of perfluorinated compounds in surface-, sea- and sewagewater using liquid chromatography coupled to time-of-flight mass spectrometry
Wille, K.; Vanden Bussche, J.; Noppe, H.; De Wulf, E.; Van Caeter, P.; Janssen, C.R.; De Brabander, H.F.; Vanhaecke, L. (2010). A validated analytical method for the determination of perfluorinated compounds in surface-, sea- and sewagewater using liquid chromatography coupled to time-of-flight mass spectrometry. J. Chromatogr. 1217(43): 6616-6622. dx.doi.org/10.1016/j.chroma.2010.03.054
In: Journal of Chromatography A. Elsevier: Amsterdam. ISSN 0021-9673; e-ISSN 1873-3778, meer
| |
Trefwoorden |
Marien/Kust; Brak water; Zoet water |
Author keywords |
PFCs; LC–ToF-MS; Accurate mass; Validation; North Sea |
Auteurs | | Top |
|
- Van Caeter, P., meer
- Janssen, C.R., meer
- De Brabander, H.F., meer
- Vanhaecke, L., meer
|
|
Abstract |
Perfluorinated compounds (PFCs), which are extensively used in a wide variety of applications because of their specific surfactant properties, have recently appeared as an important new class of global environmental pollutants. Quantitative analysis of PFCs in aqueous matrices remains, however, a challenging task. During this study, a new analytical method for the determination of 14 PFCs in surface-, sewage- and seawater was developed and validated. The target analytes were extracted using solid-phase extraction followed by liquid chromatography coupled to a time-of-flight mass spectrometer (LC–ToF-MS). The use of very narrow mass tolerance windows (<10 ppm) resulted in a highly selective MS-technique for the detection of PFCs in complex aqueous matrices. Validation of this analytical method in surface-, sewage- and seawater resulted in limits of quantification (LOQs) varying from 2 to 200 ng L-1, satisfying recoveries (92–134%), and good linearity (R2 = 0.99 for most analytes). Analysis of samples of the North Sea, the Scheldt estuary, and three harbours of the Belgian coastal region led to the detection of four different PFCs. Perfluorooctane sulfonate (PFOS) was found to be the most abundant PFC in levels up to 38.9 ng L-1. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.